Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Preview: Aqua TROLL 600 Multiparameter Sonde
Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde
Mobile Preview: Aqua TROLL 600 Multiparameter Sonde

Aqua TROLL 600 Multiparameter Sonde

Art.Nr.:
AQUATROLL600

Kundenrezensionen

  • Gast, 05.04.2024
    Die Nitratsonde ist nicht geeignet für Messungen im Grundwasser, da die im Datenblatt angegebene Messbereiche und Genauigkeiten um Größenordnungen höher ist als sie im Grundwasser gefunden werden. Ich war darüber sehr verärgert, da ich hier schlecht beraten wurde. höher ist als sie im Grundwasser gefunden werden. Ich war darüber sehr verärgert, da ich hier schlecht beraten wurde.
    Zur Rezension
  • Gast, 30.05.2023
    I think the probe is good and easy to assemble and program. Since we only used it for EC and NO3, we can say our opinion on both of them. I think the EC was not bad and easy to calibrate but had the problem of always shifting from the true measurement by a margin. Although it is stated in the manual that it is not needed to be calibrated regularly. The NO3 was not reliable in our case since our site only had lower values than the accuracy of the device. The calibration solutions also were very high, it is only suitable for very high polluted areas and not regular monitoring of groundwater. EC was not bad and easy to calibrate but had the problem of always shifting from the true measurement by a margin. Although it is stated in the manual that it is not needed to be calibrated regularly. The NO3 was not reliable in our case since our site only had lower values than the accuracy of the device. The calibration solutions also were very high, it is only suitable for very high polluted areas and not regular monitoring of groundwater.
    Zur Rezension

Zu diesem Produkt empfehlen wir Ihnen:

Unbelüftetes Rugged Twist-Lock Kabel
  • Echtzeit-Datenkommunikation
  • für nicht belüftete In-Situ-Instrumente
  • jahrelang zuverlässige Kommunikation
  • Übertragung von Modbus, SDI-12 oder 1x4-20mA  
Preis auf Anfrage
Belüftetes Rugged Twist-Lock Kable
  • Echtzeit-Datenkommunikation
  • für belüftete In-Situ-Instrumente
  • jahrelang zuverlässige Kommunikation
  • Übertragung von Modbus, SDI-12 oder 1x4-20mA 
211,45 EUR

Dieses Produkt ist z.B. kompatibel zu:

Aqua TROLL 500/600 Kupferschutz
  • verhindert biologischen Bewuchs
  • verbessert die Datengenauigkeit
  • verlängert den Einsatz
1.148,17 EUR
Für weitere Informationen besuchen Sie bitte die Homepage zu diesem Artikel.